Sterinis® evaluation report synthesis in intensive ward at Rikshospital (Copenhagen / Denmark)
By. Leif Andersen, Infeksjonshygienisk Enhed Rigshospitalet Copenhagen.
Jan-Erik Fredriksen, Health & Environment-OSLO
The target is to test Sterinis® effects in a patient room, contaminated with known micro-organisms. The disinfection effect was controlled by putting sampling germs on areas, then after to put these samples for growth analysis.
Trial design: A patient room (59m3) currently not in use at intensive ward 4131, was used for the trials. All medical apparatus were kept with in addition a respiratory device. 20 sample sites were selected and contaminated with a mixture of Serratia marcescens, Enterococcus faecalis og Bacillus cereus, all in a concentration of 107-108 CFU/ml. Sterinis® was programmed for 3 diffusion cycles of 14 minutes with contact times respectively of 30 minutes, 1 hour and 2 hours. After the disinfection, the samples were taken and put in identified petri-boxes with blood-agar for growth then the samples were put in a serum treatment during 48hours at 37°C for incubation
Results and comments:
2 samples were not sterile, these results are foreseeable and due to the extreme difficulty to reach these sample sites (This result was expected and worked like a ”positive control”):
+++ 50 cm inside of a tube-hose (rubber-tube)
+++ inside of a suction-glass with a sealed top
|
Sample place |
S. marcescens |
E. faecalis |
B. cereus |
|
On top of cupboard beside door |
0 |
0 |
0 |
|
On top of cupboard beside window |
0 |
0 |
0 |
|
Ceiling lamp by door |
0 |
0 |
0 |
|
Ceiling lamp by window |
0 |
0 |
0 |
|
Soap-dispenser holder -wall |
0 |
0 |
0 |
|
Screw holes in wall |
0 |
0 |
0 |
|
Thermostat on heater-wall |
0 |
0 |
0 |
|
Cotton curtain |
0 |
0 |
0 |
|
Under table by window |
0 |
0 |
0 |
|
Computer keyboard |
0 |
0 |
0 |
|
Respiratory hose entry |
0 |
0 |
0 |
|
Respiratory hose exit |
0 |
0 |
0 |
|
Respiratory hose middle |
+++ |
+++ |
0 |
|
Respirations mask |
0 |
0 |
0 |
|
Infusionpump |
0 |
0 |
0 |
|
Under monitor |
0 |
0 |
0 |
|
Apparatus display |
0 |
0 |
0 |
|
Top of monitor box |
0 |
0 |
0 |
|
Suction bottle |
0 |
+++ |
+++ |
Prospects: Where can Sterinis® be used at the Rikshospital:
In the following places and situations Sterinis® can be used:
- In wards or sections with out-brakes of micro-organisms without finding the source.
- In sections where there are many cases of certain types of infections (fx Clostridium difficile).
- In high-risk areas, like intensive care, neonatal ward, transplantation sections.
- In selected cases of end-disinfection of isolation wards after infected patients.
- During the re-building etc... when spores might be present.
- For disinfection of technical apparatus in high-risk areas.
- For disinfection of ambulances.
Comments:
Disinfection with Sterinis® does not last longer than traditional methods, but the disinfection performance is safer and more secure, especially for areas not easily reachable..
Evaluation report from Rigshospitalet : Full evaluation report
|